Notice Text:

Updated as of

1/13/2025

 

Listed below is a summary of the planned outages that could affect capacity or impact any receipt/delivery locations during the PEPL 2024 outage season.  This schedule is not a complete list of all outages and is subject to change as the season progresses to reflect any project delays, cancellations or additions.  Additionally, anticipated impact and restrictions are subject to change.  
*All scheduled dates represent gas days as defined in the PEPL Tariff to mean a period of twenty-four consecutive hours, beginning and ending at 9:00 a.m. (Central Clock Time).

Start Date

End Date

Location

Unit(s)

Maintenance

Anticipated Impact

Meter(s) Impact

4/30/24

6/12/24

Pelham Road

Station

Rebuild

Meters will be shut in for the duration of the outage.

02997-RIVER ROUGE PLANT
02513-DETROIT

5/1/24

5/20/24

Pelham Road

Station

Rebuild

Meter will be shut in for the duration of the outage.

Location: UNION

5/2/24

5/10/24

Sooner

16"

Relay at Hwy 33 and HDD

Meters will be shut in for the duration of the outage.

10632-DFS-KINGFISHER
41433-CHISOLM PLANT
41447-REEDING PLANT
41434-LINCOLN PLANT

5/2/24

5/10/24

Cashion

Station

Isolation ESD

Capacity through Cashion Station may be limited.  Meter subject to scheduling reductions.

10632-DFS-KINGFISHER

5/9/24

5/17/24

Edgerton

100 Line

Anomaly Repair

All meters downstream of MP 833.38 subject to scheduling reductions.

02654-IDA
02611-CARLETON
02997-RIVER ROUGE PLANT
05586-GUARDIAN GLASS
Location:UNION
Location:NATST
Location:MCON

5/28/24

5/28/24

West Line

100 Line

Tool Run

Meter will be shut in for the duration of the outage.

09874-KALAMAZOO RIVER GENERATION STATION/COMSTOCK

5/30/24

5/30/24

West Line

100 Line

Tool Run

Meter will be shut in for the duration of the outage.

09874-KALAMAZOO RIVER GENERATION STATION/COMSTOCK

6/4/24

6/4/24

West Line

100 Line

Tool Run

Meter will be shut in for the duration of the outage.

09874-KALAMAZOO RIVER GENERATION STATION/COMSTOCK

6/6/24

6/6/24

West Line

100 Line

Tool Run

Meter will be shut in for the duration of the outage.

09874-KALAMAZOO RIVER GENERATION STATION/COMSTOCK

6/6/24

6/21/24

Haven

200 Line

Coupling reinforcements and valve replacements

Meter will be shut in for the duration of the outage.

09225-GETTY GAS-BURNS

6/17/24

6/28/24

Fulton

Lateral

Pipe Replacement

Meter will be shut in for the duration of the outage.

02085-HARBISON-WALKER-FULTON

6/18/24

6/18/24

DOGWOOD

Meter

Tie-In after Hydrotest

Meter will be shut in for the duration of the outage.

09236-DOGWOOD

6/21/24

6/27/24

ONEOK GAS

Meter

Meter Upgrades

Meter will be shut in for the duration of the outage.

09069-ONEOK GAS TRANSPORTATION

7/8/24

7/30/24

Edgerton

100 Line

Anomaly Digs

Location will be subject to scheduling reductions.

Location: MCON

7/9/24

7/9/24

Edgerton

200 Line

Hydrotest

Meter will be shut in for the duration of the outage.

02853-RICHLAND POWER PLANT

7/10/24

7/10/24

Edgerton

200 Line

Hydrotest

Meter will be shut in for the duration of the outage.

02781-ANR PIPELINE CO.DEL.

8/6/24

8/6/24

Edgerton

200 Line

Hydrotest

Meters will be shut in for the duration of the outage.

02781-ANR PIPELINE CO.DEL.
02853-RICHLAND POWER PLANT

8/20/2024

8/26/2024

Nipsco Defiance-Crossroads Delivery

M&R

Painting

Meter will be shut in for the duration of the outage.

Location: CRSRD

9/10/2024

9/13/2024

West Line

100 Line

Immediate Anomaly Dig

Meters will be shut in for the duration of the outage.

02551-KALAMAZOO
09874-KALAMAZOO RIVER GENERATION/COMSTOCK

10/1/24

10/16/24

Sunray

100 Line

Gate replacement

Meters will be shut in for the duration of the outage.

12840-SEABOARD FARMS-WITTAKER 1-6
40524-SUNRAY GAS PLANT

10/1/24

10/2/24

Northern Natural-Greensburg

M&R

New RTU Installation

Meter will be shut in for the duration of the outage.

Location: NNATL

10/10/24

10/15/24

Seiling

100 Line

Valve Replacement

Capacity through Elk City and Seiling will be limited.  Meters will be shut in for the duration of the outage.

41420-MCCLURE INTERCONNECT
40466-ENOGEX-BECKHAM-WIT.
41215-DELHI CARPENTER RECEIPT
12744-ENBRIDGE-BECKHAM COUNTY
12666-ARKLA/NORAM-CUSTER RECEIVED
13241-MARK WEST GAS RECEIPT
41413-ONEOK SMALLWOOD
06132-K.N. ALEDO CHECK PURCHASE
41393-NINE MILE PLANT
41180-TAYLOR PLANT
09069-ONEOK GAS TRANSPORTATION
Location: HEMPH

10/11/24

10/15/24

Seiling

100 Line

Pipe Replacement

Capacity through Elk City and Seiling will be limited.  Meters will be shut in for the duration of the outage.

41420-MCCLURE INTERCONNECT
40466-ENOGEX-BECKHAM-WIT.
41215-DELHI CARPENTER RECEIPT
12744-ENBRIDGE-BECKHAM COUNTY
12666-ARKLA/NORAM-CUSTER RECEIVED
13241-MARK WEST GAS RECEIPT
41413-ONEOK SMALLWOOD
06132-K.N. ALEDO CHECK PURCHASE
41393-NINE MILE PLANT
41180-TAYLOR PLANT
09069-ONEOK GAS TRANSPORTATION
02428-PHIL CIM PURCHASE #1
Location: HEMPH
41424-ROSE VALLEY PLANT
Location: WTANA

11/5/24

11/11/24

Hooker

16"

Replace receiving barrel

Meters will be shut in for the duration of the outage.

41152-DORCHESTER HUGOTON-MOUSER
41296-MOBILE MOUSER-DEFS STRT
Location: BAKER